<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Norstat Industrial Safety &#38; Automation Blog</title>
	<atom:link href="http://www.norstatblog.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.norstatblog.com</link>
	<description>Your Safety and Automation Specialist</description>
	<lastBuildDate>Tue, 15 Jun 2010 15:02:59 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title></title>
		<link>http://www.norstatblog.com/2010/06/206/</link>
		<comments>http://www.norstatblog.com/2010/06/206/#comments</comments>
		<pubDate>Tue, 15 Jun 2010 14:58:38 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Industrial Automation]]></category>
		<category><![CDATA[Special Offers]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=206</guid>
		<description><![CDATA[DIN 43650 Solenoid Valve Connection Systems
Norstat and DIN are synonymous in the Fluid Power Industry. Norstat was the
first in 1982 to introduce the North American market to the concept of a
European DIN Connector with a Robust IP67, Encapsulated, Molded Cable Design.
We have been providing technological enhancements to this market ever since.
Today we offer the full [...]]]></description>
			<content:encoded><![CDATA[<h2 style="text-align: center;"><span style="text-decoration: underline;">DIN 43650 Solenoid Valve Connection Systems</span></h2>
<p style="text-align: center;">Norstat and DIN are synonymous in the Fluid Power Industry. Norstat was the<br />
first in 1982 to introduce the North American market to the concept of a<br />
European DIN Connector with a Robust IP67, Encapsulated, Molded Cable Design.<br />
We have been providing technological enhancements to this market ever since.<br />
Today we offer the full range of DIN connectors and accessories fully stocked<br />
in Rockaway, NJ.</p>
<p style="text-align: center;">DIN 43650 or EN 175301-803 Connectors are robust and reliable quick-disconnect<br />
alternatives to handwiring of DIN style solenoid valves on the factory floor.<br />
Norstat/HTP offers a complete range of DIN field-attachable connectors,<br />
DIN molded encapsulated cable connectors and DIN accessories.  DIN connectors<br />
are available in all voltages with LED for indication, and Suppression Protection<br />
to remove dangerous back EMI.  The connectors are available in Form A 18mm,<br />
Industrial Form B 11mm, DIN 43650 Form B 10mm, Industrial Form C 9.4mm and<br />
DIN 43650 Form C 8mm.</p>
<p style="text-align: center;"><a href="http://www.norstatblog.com/wp-content/uploads/din-connectos.jpg"><img class="size-full wp-image-208 aligncenter" title="din connectos" src="http://www.norstatblog.com/wp-content/uploads/din-connectos.jpg" alt="" width="429" height="162" /></a></p>
<p style="text-align: center;">DIN connectors are manufactured to meet the hydraulic and pneumatic standards<br />
for quick-disconnect connectors on solenoid valves, pressure switches and<br />
transducers. Norstat and HTP connectors support all DIN 43650 valves, providing<br />
connection solutions for all your requirements.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/06/206/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mosaic</title>
		<link>http://www.norstatblog.com/2010/06/161/</link>
		<comments>http://www.norstatblog.com/2010/06/161/#comments</comments>
		<pubDate>Wed, 02 Jun 2010 19:48:40 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Special Offers]]></category>
		<category><![CDATA[Modular Safety Integrated Controller]]></category>
		<category><![CDATA[Mosaic]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=161</guid>
		<description><![CDATA[    Mosaic
Modular Safety Integrated Controller (MoSaIC)
 
MOSAIC is the new modular and configurable safety controller from Norstat and REER.
 
This new safety device is capable of monitoring many safety sensors and commands at the same time. These can be safety light curtains, safety photocells, emergency stops, safety mats, magnetic or mechanical safety switches, two-hand controls, etc.
 
Thanks to [...]]]></description>
			<content:encoded><![CDATA[<h5 style="text-align: center;"><img class="ngg-singlepic ngg-left" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/mosaic-pic.jpg" alt="mosaic-pic" width="321" height="281" />    Mosaic<br />
Modular Safety Integrated Controller (MoSaIC)</h5>
<p style="text-align: center;"> </p>
<p>MOSAIC is the new modular and configurable safety controller from Norstat and REER.<br />
 <br />
This new safety device is capable of monitoring many safety sensors and commands at the same time. These can be safety light curtains, safety photocells, emergency stops, safety mats, magnetic or mechanical safety switches, two-hand controls, etc.<br />
 <br />
Thanks to MOSAIC&#8217;s modular and expandable structure, it is possible to adapt its I/O configuration and functionality to the demands of each application. This makes MOSAIC a highly versatile and flexible safety controller.</p>
<p> MOSAIC has solid state and/or relay outputs.  They can be instantaneous or delayed.<br />
    </p>
<p>    <strong>Main Features</strong></p>
<ul>
<li>Configurable safety controller </li>
<li>Safety level: SIL 3, PLe, Cat. 4 </li>
<li>Easy and intuitive graphic configuration software (MSD &#8211; Mosaic Safety Designer) </li>
<li>Compact design:<br />
     Single Main module dimensions 22.5 x 99 x 114.5 mm</li>
<li>Max 72 inputs and 8 OSSD pairs </li>
<li>Max 7 expansion units in addition to Master M1 </li>
<li>M1 stand alone main unit: <br />
 8 safety inputs, 2 OSSD pairs with separate EDM and Start/Restart    configurable via PC through USB interface</li>
<li>MI8O2 expansion unit: <br />
8 safety inputs, 2 OSSD pairs with separate EDM and Start/Restart</li>
<li>MI8 and MI16 expansion units: <br />
With 8 and 16 safety inputs</li>
<li>MO2 and MO4 expansion units: <br />
With 2 and 4 OSSD pairs with separate EDM and Start/Restart</li>
<li>MR2 and MR4 relay units: <br />
With 2 and 4 guided contacts safety relays</li>
<li>MB expansion units for connection to the most common industrial Fieldbus systems: <br />
PROFIBUS DP, DeviceNet, CANopen</li>
<li> Memory card configuration storage (MCM &#8211; Mosaic Configuration Memory)</li>
</ul>
<p>   <strong>Safety Communication</strong></p>
<p>Communication between units via proprietary high speed bus (MSC &#8211; Mosaic Safety Communication) Simple diagnostics via LED signaling and configuration software. <br />
 </p>
<p>   <strong>Mosaic Safety Designer (MSD)<br />
</strong> <br />
Mosaic Safety Designer (MSD) software is a user-friendly configuration tool which makes the programming of MOSAIC possible in just a few simple steps.  By clicking on the functional icons it is easy to &#8216;Drag &amp; Drop&#8217; and configure any of the many safety functions.<br />
 <br />
Thanks to an accurate functional test incorporated into the Mosaic Safety Designer (MSD) software, configuration errors are detected immediately. This also helps to guarantee that configuration errors cannot lead to an unsafe situation and valuable time is not lost during the commissioning of the machine.<br />
 <br />
In addition, the multi-level password management of Mosaic Safety Designer (MSD) gives further security against non-authorized access to the configuration software. <br />
 <br />
MCM is a memory card which can be used to save the configuration data for copying to a new MOSAIC safety controller as and when required.<br />
 <br />
 Safety level:<br />
Cat. 4<br />
SIL 3 &#8211; SILCL 3<br />
PL e &#8211; Cat. 4</p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/06/161/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Safety &amp; Automation Offering</title>
		<link>http://www.norstatblog.com/2010/04/safety-automation-offering/</link>
		<comments>http://www.norstatblog.com/2010/04/safety-automation-offering/#comments</comments>
		<pubDate>Tue, 06 Apr 2010 15:22:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[ENTRY & EXIT Muting System]]></category>
		<category><![CDATA[EOS line of miniature integrated Type 4 safety light curtains]]></category>
		<category><![CDATA[Norstat]]></category>
		<category><![CDATA[Palletizing]]></category>
		<category><![CDATA[REER JANUS MUTING Light Curtains]]></category>
		<category><![CDATA[Robotic Cells]]></category>
		<category><![CDATA[safety light curtains]]></category>
		<category><![CDATA[Wrapping]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=117</guid>
		<description><![CDATA[News and Special Offers March 2010
NORSTAT Special Limited Time Offer
REER JANUS MUTING Light Curtains
A Complete ENTRY &#38; EXIT Muting System for Palletizing, Wrapping, Robotic Cells for $1200.00
Increase productivity while cutting cost with the Janus Muting Light Curtain featuring built in muting control having all safety functions integrated inside the Emitter and Receiver.  Contact Norstat or [...]]]></description>
			<content:encoded><![CDATA[<p>News and Special Offers March 2010</p>

<a href="http://www.norstatblog.com/wp-content/gallery/reer-new/reer.gif" title="" class="shutterset_singlepic12" >
	<img class="ngg-singlepic ngg-left" src="http://www.norstatblog.com/wp-content/gallery/cache/12__320x240_reer.gif" alt="reer" title="reer" />
</a>

<h1>NORSTAT Special Limited Time Offer</h1>
<h2>REER JANUS MUTING Light Curtains</h2>
<p>A Complete ENTRY &amp; EXIT Muting System for Palletizing, Wrapping, Robotic Cells for $1200.00</p>
<p>Increase productivity while cutting cost with the Janus Muting Light Curtain featuring built in muting control having all safety functions integrated inside the Emitter and Receiver.  Contact Norstat or your local distributor for a price quotation and technical assistance with your application.  Upgrade NOW and meet the stringent safety requirements<br />
IEC/TS 62046 in material handling applications.<br />
<a title="Norstat Industrial Automation" href="http://www.norstat.com">www.norstat.com</a> www.norstatblog.com<br />
PH: 973 586-2500</p>
<h2>EOS – NEW MODELS NOW AVAILABLE</h2>

<a href="http://www.norstatblog.com/wp-content/gallery/eos-new/productnewseos.jpg" title="" class="shutterset_singlepic16" >
	<img class="ngg-singlepic ngg-left" src="http://www.norstatblog.com/wp-content/gallery/cache/16__320x240_productnewseos.jpg" alt="productnewseos" title="productnewseos" />
</a>

<p>A few months have passed since our launch of the new EOS line, of miniature, integrated Type 4, safety light curtains. We are pleased to announce the availability of more versions.</p>
<p>The EOS4 product range widens, with the addition of new models with 14 mm resolution &#8211; 6 m range,  and versions having a 20 m operating range. The slim package, 28mm X 30mm and zero dead zone make this a excellent choice for limited space applications.</p>
<p><a title="Norstat Industrial Automation" href="http://www.norstat.com">www.norstat.com</a> www.norstatblog.com     PH: 973 586-2500</p>
<h3>IP67 WATERTIGHT ENCLOSURE FOR FOOD &amp; BEVERAGE INDUSTRY</h3>

<a href="http://www.norstatblog.com/wp-content/gallery/ip67-enclosure/ip-67-enclosure.jpg" title="" class="shutterset_singlepic17" >
	<img class="ngg-singlepic ngg-left" src="http://www.norstatblog.com/wp-content/gallery/cache/17__320x240_ip-67-enclosure.jpg" alt="ip-67-enclosure" title="ip-67-enclosure" />
</a>

<p>The Food industry is a demanding environment when you are talking about electrical or electronic components. They have to withstand high pressure and high temperature wash down processes.<br />
REER has developed a special version of its watertight enclosures (WTF / WTFH), made of resistant materials suitable for this industry. Our ADMIRAL, EOS and JANUS Series light curtains can be placed inside the fully sealed enclosure ready for installation.</p>
<p><a title="Norstat Industrial Automation" href="http://www.norstat.com">www.norstat.com</a> www.norstatblog.com  PH: 973 586-2500 2010</p>
<p><a title="Norstat Blog RSS Feed" href="http://www.norstatblog.com/feed/">Subscribe</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/04/safety-automation-offering/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>REER JANUS MUTING Light Curtains $1200.00</title>
		<link>http://www.norstatblog.com/2010/04/reer-janus-muting-light-curtains-1200-00/</link>
		<comments>http://www.norstatblog.com/2010/04/reer-janus-muting-light-curtains-1200-00/#comments</comments>
		<pubDate>Thu, 01 Apr 2010 18:13:10 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Industrial Automation]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=108</guid>
		<description><![CDATA[



Announces a Special Limited Time Offer On REER JANUS MUTING Light Curtains
A Complete ENTRY/EXIT &#38; EXIT Only Muting System for   Palletizing, Wrapping, &#38; Robotic Cells for $1200.00
Janus Series Light Barriers, Safety Innovation For Material Handling
The Janus M range   of muting light barriers is a very unique product that has been designed  [...]]]></description>
			<content:encoded><![CDATA[<table border="0" cellspacing="0" cellpadding="0" width="749" align="left">
<tbody>
<tr>
<td width="100%">
<a href="http://www.norstatblog.com/wp-content/gallery/reer/reer-janus-muting-offer-3.jpg" title="" class="shutterset_singlepic10" >
	<img class="ngg-singlepic" src="http://www.norstatblog.com/wp-content/gallery/cache/10__320x240_reer-janus-muting-offer-3.jpg" alt="reer-janus-muting-offer-3" title="reer-janus-muting-offer-3" />
</a>
</p>
<p><strong>Announces a Special Limited Time Offer On REER JANUS MUTING Light Curtains</strong></p>
<p>A Complete ENTRY/EXIT &amp; EXIT Only Muting System for   Palletizing, Wrapping, &amp; Robotic Cells for $1200.00</p>
<p>Janus Series Light Barriers, Safety Innovation For Material Handling</p>
<p><a title="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w==" href="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w=="></a><a title="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w==" href="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w=="></a><a title="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w==" href="http://rs6.net/tn.jsp?e=0012DzKuUr1ZO2XGr1oF1qncc-LhrYTm4U85SqZOoMg91mNJZqoZfHWh0v0kThTF9_5v5pAX0z89uUFXvjJhz6M0AIIsQbP1kJ6359OtXjsWVm9ixgdcesI_w=="></a>The Janus M range   of muting light barriers is a very unique product that has been designed   specifically for protecting personnel in Material Handling   Applications, such as Palletizing, Machine Conveying, Wrapping,   Loading/Unloading, and Robotic applications. Anywhere muting is   integral to the flow of material.</p>
<p>The Janus, with   built-in muting control, dual safe static outputs, and optional built in   muting sensors, can work without external control units having all the safety   functions integrated inside the Emitter and the Receiver.    This complies harmoniously with the requirements of   the Standard EN 61496-1, the International Standard IEC 61496-1-2   and CSA Z432-04 &#8211; Safeguarding of Machinery.</p>
<p>The benefits of   the Janus M Series Light Curtains are:</p>
<ul>
<li>Extremely        easy connection and installation, thanks to the M12, 5-pole (emitter)        and M23 19-pole (receiver) standard connectors.</li>
<li>Use        of standard cables up to 100 m long.  No need for shielded        cables.</li>
<li>Settings        of each function are integrally performed via the connector.         Patented solutions allow the installer to perform a wide range of user        friendly configurable functions with only a few connector pins. No        need for software or dip-switch settings on the light curtain for the        configuration!  The end user can replace a product without the        possibility of errors or the necessity of a skilled operator!</li>
<li>Integration        of the main safety functions, including self-monitoring of the safety        circuits and, the external device monitoring (EDM) and the Start/Restart        interlock functions.</li>
<li>Long        Range 40mm resolution version available with up to 60m (197’) sensing        range</li>
</ul>
<ul>
<li> Integration of   the Muting function and of the Muting sensors (ML and MT   models).  All Muting parameter settings (Muting timeout, override,   etc.), via the receiver connector and/or the MJB connection boxes.</li>
</ul>
<p>Contact us to get your system   quoted Today</p>
<p>300     Roundhill Drive, Rockaway, New     Jersey, T- 973-586-2500, F-973-586-1590,    <a href="http://www.norstat.com/">www.norstat.com</a> <a href="../">www.norstatblog.com</a></td>
</tr>
</tbody>
</table>
<p>﻿</p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/04/reer-janus-muting-light-curtains-1200-00/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Safety Relays with Force Guided Design vs. Traditional Electromechanical Relays</title>
		<link>http://www.norstatblog.com/2010/01/safety-relays-with-force-guided-design-vs-traditional-electromechanical-relays/</link>
		<comments>http://www.norstatblog.com/2010/01/safety-relays-with-force-guided-design-vs-traditional-electromechanical-relays/#comments</comments>
		<pubDate>Wed, 27 Jan 2010 17:30:05 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Riese Safety Relays]]></category>
		<category><![CDATA[Traditional Electromechanical Relays]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=72</guid>
		<description><![CDATA[Safety Relays with Force Guided Design
A traditional electromechanical relay consists of a set of contacts that open or close, depending on their arrangement and the coil voltage. A Riese safety relay&#8217;s contact design is mechanically interlocked. Mechanically interlocking the contacts enables the relay&#8217;s behavior to operate in a predetermined fashion and is achieved by either [...]]]></description>
			<content:encoded><![CDATA[<h1>Safety Relays with Force Guided Design</h1>
<p>A traditional electromechanical relay consists of a set of contacts that open or close, depending on their arrangement and the coil voltage. A Riese safety relay&#8217;s contact design is mechanically interlocked. Mechanically interlocking the contacts enables the relay&#8217;s behavior to operate in a predetermined fashion and is achieved by either applying the mechanical interlock or force guiding the contact set.</p>
<p>The design using a mechanical bar interlinking all the contacts assures that all normally open (N/O or Form A) contacts don&#8217;t close if the normally closed (N/C or Form B) contacts don&#8217;t open. If the contacts of either the N/O or the N/C type are welded shut, the bar prevents the opposing contact type from operating. Therefore, when a relay contact fails to open, the opposing (or other) contacts don&#8217;t close enabling a monitored state of the relay.  This design is the heart of RIESE SAFETY RELAYS and provide detection of a single fault, redundancy in the contacts and monitoring of the safety devices. In addition, the N/C and N/O contact may not be closed simultaneously.</p>
<p>When experiencing a fault, a safety relay&#8217;s contacts go into an undefined state. In the event that a relay contact welds together or fails to open, fault tolerance is achieved by allowing all the possible contact sets to open to a gap larger than 0.5 millimeters. This is the minimum contact set for a safety relay consists of a Form A (N/O) and Form B (N/C) contact.</p>
<p>With automated machines and processes, hazardous motion is typically present posing potential danger. The goal of any safety circuit, is to provide protection  for the operator, the machine, and even the processes. The use of Riese Safety Relays with force guided, redundant, monitored circuit design results in reduced danger, control reliability, single fault tolerance and improved safety.</p>
<p>Installing safety devices such as guards and gates, light curtains, safety mats, pull cord switches, foot switches, two hand control devices etc&#8230;.. Don&#8217;t in and of themselves create a safe machine.  It is the use of the Riese Safety Relay behind these devices that assure the output from any of these safety devices is correctly and reliably sent to the stopping control circuit.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/01/safety-relays-with-force-guided-design-vs-traditional-electromechanical-relays/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mechan SS-R 21 Electronically Coded Safety Switch</title>
		<link>http://www.norstatblog.com/2010/01/mechan-ss-r-21-electronically-coded-safety-switch/</link>
		<comments>http://www.norstatblog.com/2010/01/mechan-ss-r-21-electronically-coded-safety-switch/#comments</comments>
		<pubDate>Tue, 26 Jan 2010 16:08:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Mechan Safety Switch]]></category>
		<category><![CDATA[Electronically Coded Safety Switch]]></category>
		<category><![CDATA[Mechan]]></category>
		<category><![CDATA[Mechan SS-R 21]]></category>

		<guid isPermaLink="false">http://www.norstatblog.com/?p=59</guid>
		<description><![CDATA[Mechan SS-R 21 Electronically Coded Safety Switch
The new SS-R 21DC-10M features 2 normally open and 1 normally closed contacts, a dual color LED which is red when the guard is open, and green when the guard is closed.  The  SS-R has volt free contacts so it is not polarity sensitive, and the out put  contact [...]]]></description>
			<content:encoded><![CDATA[<h1 style="text-align: center;">Mechan SS-R 21 Electronically Coded Safety Switch</h1>
<p>The new SS-R 21DC-10M features 2 normally open and 1 normally closed contacts, a dual color LED which is red when the guard is open, and green when the guard is closed.  The  SS-R has volt free contacts so it is not polarity sensitive, and the out put  contact is capable of switching higher current at higher voltage up to 2A.  This switch has been designed to replace the BTI but with the added benefit of polarity independence and greater current output contacts to drive more optional devices in the safety circuit.  I have also attached information on our full MagnaSafe line including the MS 7. The MagnaSafe program features a cost effective solution utilizing a magnetically coded safety switch.  Let me know if you would like a sample as well as your requirements for the machines you are producing now.  Thanks for the opportunity and if you have any questions please call on me.</p>
<p><a href="http://clients.digipage.co.uk/?id=mechan_controls_plc">http://clients.digipage.co.UK/?id=mechan_controls_plc</a> Catalog brochure and technical link.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2010/01/mechan-ss-r-21-electronically-coded-safety-switch/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>Norstat your voice in the industrial automation and safety space</title>
		<link>http://www.norstatblog.com/2009/12/norstat-industrial-automation-safety/</link>
		<comments>http://www.norstatblog.com/2009/12/norstat-industrial-automation-safety/#comments</comments>
		<pubDate>Sat, 19 Dec 2009 06:10:21 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Industrial Automation]]></category>

		<guid isPermaLink="false">http://norstatblog.com/?p=1</guid>
		<description><![CDATA[Norstat Industrial Automation &#38; Safety
Since 1962 Norstat, has been servicing the industrial automation marketplace by offering safety and automation solutions to the machine and process control industries with a complete line of safety, control, and automation products.  Our trained engineering staff both in Rockaway and in the field close to our customers can offer expert [...]]]></description>
			<content:encoded><![CDATA[<h1 style="text-align: center;">Norstat Industrial Automation &amp; Safety</h1>

<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/reer-safety-curtain-display.jpg" title="" class="shutterset_singlepic8" >
	<img class="ngg-singlepic" src="http://www.norstatblog.com/wp-content/gallery/cache/8__320x240_reer-safety-curtain-display.jpg" alt="reer-safety-curtain-display" title="reer-safety-curtain-display" />
</a>

<p>Since 1962 Norstat, has been servicing the industrial automation marketplace by offering safety and automation solutions to the machine and process control industries with a complete line of safety, control, and automation products.  Our trained engineering staff both in Rockaway and in the field close to our customers can offer expert solutions for all your safety and automation requirements.</p>
<p>Our SAFETY program includes Safety Interlocks and Non Contact Safety Switches, Safety Control Relays and Audible and Visual Signaling Devices.  Our AUTOMATION program includes, Foot Switches and Limit Switches for axis control, and Connectors for sensors and solenoid valves.  Our program enables you to conform to both the domestic and international safety standards.<br />
MISSION STATEMENT</p>
<p>Our goal is to offer our customers the most comprehensive, synergistic and state of the art program of Safety and Automation products providing the best solutions to their application requirements.  We accomplish the task through an engineering and sales staff that comprises the best and the brightest in the field of technology.  We have worldwide experience in supporting our customers and are the “Source for all your Safety and Automation” needs.</p>
<p>Get Safe</p>
<p>Get Automated</p>

<div class="ngg-galleryoverview" id="ngg-gallery-1-1">


	<!-- Piclense link -->
	<div class="piclenselink">
		<a class="piclenselink" href="javascript:PicLensLite.start({feedUrl:'http://www.norstatblog.com/wp-content/plugins/nextgen-gallery/xml/media-rss.php?gid=1&amp;mode=gallery'});">
			[View with PicLens]		</a>
	</div>
	
	<!-- Thumbnails -->
		
	<div id="ngg-image-1" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-din-connectors-assemblies.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-din-connectors-assemblies" alt="norstat-din-connectors-assemblies" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-din-connectors-assemblies.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-2" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-industrial-automation-inventory.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-industrial-automation-inventory" alt="norstat-industrial-automation-inventory" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-industrial-automation-inventory.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-3" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-inventory-safety-switches.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-inventory-safety-switches" alt="norstat-inventory-safety-switches" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-inventory-safety-switches.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-4" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-inventory.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-inventory" alt="norstat-inventory" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-inventory.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-5" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-non-contact-safety-switches.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-non-contact-safety-switches" alt="norstat-non-contact-safety-switches" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-non-contact-safety-switches.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-6" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-safety-position-switches.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-safety-position-switches" alt="norstat-safety-position-switches" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-safety-position-switches.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-7" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/norstat-safety-relays-controls.jpg" title=" " class="shutterset_set_1" >
								<img title="norstat-safety-relays-controls" alt="norstat-safety-relays-controls" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_norstat-safety-relays-controls.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-8" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/reer-safety-curtain-display.jpg" title=" " class="shutterset_set_1" >
								<img title="reer-safety-curtain-display" alt="reer-safety-curtain-display" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_reer-safety-curtain-display.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-18" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/mosaic-pic.jpg" title=" " class="shutterset_set_1" >
								<img title="mosaic-pic" alt="mosaic-pic" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_mosaic-pic.jpg" width="93" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-19" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/loose-actuators.jpg" title=" " class="shutterset_set_1" >
								<img title="loose-actuators" alt="loose-actuators" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_loose-actuators.jpg" width="90" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-20" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/safety-swtich-single.jpg" title=" " class="shutterset_set_1" >
								<img title="safety-swtich-single" alt="safety-swtich-single" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_safety-swtich-single.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-21" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/single-switch.jpg" title=" " class="shutterset_set_1" >
								<img title="single-switch" alt="single-switch" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_single-switch.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-22" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/single-switch-2.jpg" title=" " class="shutterset_set_1" >
								<img title="single-switch-2" alt="single-switch-2" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_single-switch-2.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 		
	<div id="ngg-image-23" class="ngg-gallery-thumbnail-box"  >
		<div class="ngg-gallery-thumbnail" >
			<a href="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/din-connectos.jpg" title=" " class="shutterset_set_1" >
								<img title="din-connectos" alt="din-connectos" src="http://www.norstatblog.com/wp-content/gallery/norstat-industrial-automation-photos/thumbs/thumbs_din-connectos.jpg" width="100" height="75" />
							</a>
		</div>
	</div>
	
		
 	 	
	<!-- Pagination -->
 	<div class='ngg-clear'></div>
 	
</div>


]]></content:encoded>
			<wfw:commentRss>http://www.norstatblog.com/2009/12/norstat-industrial-automation-safety/feed/</wfw:commentRss>
		<slash:comments>4</slash:comments>
		</item>
	</channel>
</rss>
